Properties:
- self-priming, i.e. in many cases no additional blower required
- high separation efficiency over the entire operating range
- good absorption behaviour, even with considerable flow rate fluctuations
- Module consisting of jet scrubber and column
- integrated pump
- optional: heat exchanger can be installed
- optional: measuring and control equipment (e.g. pH, redox, temperature, density and/or level control)
- compact design
- many expansion options
- self-supporting on base frame
- easily tranportable
- inexpensive
- various materials possible, e.g. thermoplastics, GFK (also with liner), stainless steel, steel with liner (rubber coating), special materials (alloy, enamel), etc.
Applications for compact scrubbers:
- direct gas cooling
- Pre-saturation (possibly quench head needed)
- physical absorption
- Chemisorption
- Dust separation
- Condensation
- Combination of cooling, absorption and dust separation
- Pilot plants in laboratories or technical schools
- Emergency units (e.g. HCl or chlorine emergency unit)
Compact scrubbers – Main dimensions (VUM-Standard)
type, nominal size | rate of gasflow | liquid content | main dimensions | |||
---|---|---|---|---|---|---|
N1 (mm) | m³/h | l | A (mm) | B (mm) | C (mm) | D (mm) |
KW100 | 60-240 | 400 | 1200 | 800 | 2700 | 3500 |
KW150 | 100-500 | 400 | 1200 | 800 | 2700 | 3500 |
KW200 | 300-1000 | 1000 | 1750 | 1000 | 4000 | 4500 |
KW250 | 800-1500 | 1250 | 2000 | 1000 | 4000 | 5000 |
KW300 | 1000-2200 | 2000 | 2300 | 1400 | 4000 | 5000 |