Jet fans

Properties and applications of jet fans

Properties:

  • simple construction
  • low wear (nozzle only)
  • no rotating parts
  • no problems with sealing
  • maintenance-free
  • horizontal and vertical gas supply
    to be integrated into pipelines
  • low space requirement
  • variable (length, diameter, design etc.)
  • cost-effective
  • various materials possible, e.g. thermoplastics, GFK (also with liner), stainless steel, steel with liner (rubber coating), special materials (alloy, enamel), etc.

Possible applications:

  • Extraction of air, gases and vapours
  • Emergency extraction

Dimensions:

The jet fans are characterised by their simple construction, their variability and their small space requirement. The main dimensions of the jet fans (VUM standard) are listed in the table.

Other sizes (e.g. DN600) or other dimensions as well as larger load ranges are possible. Please contact us! We will be pleased to provide you with an offer tailored to your individual requirements and wishes.

Jet fans - Main dimensions (VUM-Standard)

gas inlet-
nominal size
range
of gas
flowrate
20-150 %
main dimensions
DN (mm)m³/hA (mm)B (mm)C (mm)
506011001000150
8015012001080200
10023013001140250
15050015001310300
20090017001480350
250140019001650350
300200021001850400
400360021001800500
500450024002100600

Please request for other flowrates or dimensions if you need.